News

Company News

Classification and characteristics of pleated filter elements
发布时间:2021-10-28 15:07:52

Polypropylene pleated filter element is a depth filter element, which is usually used for preheating, clarifying filtration and terminal filtration of liquids. It has the following characteristics: ultra-fine polypropylene fiber membrane is used as the filter medium, low pressure difference, high flux, good filtration accuracy, low economic cost, all polypropylene structure, end cap, shell and center rod are all made of polypropylene Material; sintered by hot-melt process, that is, PP and PP are melted and bonded without any binder; it has a wide range of chemical compatibility; it has a series of apertures and a variety of interface forms.

product category: 

1: Polypropylene (PP) pleated filter element----universal fine filter element

2: Polyethersulfone (PES) pleated filter element ---- sterilization type fine filter element

3: Polytetrafluoroethylene (PTFE) pleated filter element----high temperature gas sterilization type fine filter element

4: Nylon membrane (N66) pleated filter element----sterilization type fine filter element

5: Polyvinylidene fluoride membrane (PVDF) pleated filter element ---- sterilization type fine filter element.

Working temperature and differential pressure:

Type A<60℃ Differential Pressure 2bar----Polypropylene Material

Type B<80℃ differential pressure 2bar----high temperature resistant material

C type <95℃ differential pressure 1bar----imported polypropylene and stainless steel material

D type <125℃ differential pressure 1bar----PVDF material

Flow: 0.5 M3 per 10 inches

Features of pleated filter element

Made of 100% polypropylene without any adhesive, minimizing leachables from the filter cartridge itself.

Excellent chemical compatibility, suitable for filtration of strong acids, alkalis and organic solvents.

The filter membrane is deep filtration, with strong dirt holding capacity and long service life.

Good high temperature resistance, can withstand repeated high temperature and high pressure sterilization, or continuous use at high temperature.

Technical parameters of pleated filter element

Filtration precision: 0.22m, 0.45m, 1m, 3m, 5m, 10m, 20m, 30m.

Applicable PH value: 1-13.

Maximum differential pressure: 25°C, forward 0.4Mpa, reverse 0.2Mpa.

Working temperature: under 0.25Mpa,

a. General type<70°C

b. High temperature type <90°C.

Sterilization: Resistant to 126°C, in-line steam sterilization for 30 minutes.

Endotoxin: The water extract of the filter column is tested by lAL, and the endotoxin content is less than 0.5EU/ml.


>